Ferrolux Line Tracer – Accessories
Ferrolux Line Tracer – Accessories
|
Mini Antenna FLA 10
Multifunctional mini antenna for:
- Secure cable identification with the twisted field method
- Pre-selecting cables with Signal Select function
- Cable fault direction determination with the twisted field method
- Selective line tracing in buildings
- Frequencies: 491 Hz, 982 Hz, 8440 Hz
- Protection class: IP 54
|
Step-voltage-probe DEB 3-10
Rugged and ergonomical step-voltage-probe for:
- Sheath and cable fault location with capacitive step-voltage-coupling
- Sheath and cable fault location with galvanic step-voltage-coupling
- Location of insulation faults on pipelines, protected by cathodic
anti-corrosion, with capacitive and galvanic coupling
- Location of cable rings and loops with capacitive coupling
- Frequencies: 491 Hz, 982 Hz, 8440 Hz
- Weight: 2.5 kg
- Dimensions: approx. 80 cm x 55 cm x 5 cm
|
Transmitter Tong UZ 100
Transmitter tongs for audio frequency signal transmission on objects up to 100 mm in diameter (and cable selection with instrument ALE 20)
- Frequencies: 400 Hz … 10 kHz
- Power: max. 10 Watt
|
Flexible converter UZF 150
Flexible tong with metal core for cable selection and audio frequency coupling up to 2 Watt for objects with 150 mm diameter
- Frequencies: 800 Hz…. 10 kHz
- Power: max. 2 Watt
|
|
Pig Sonde
Pig sonde for the location of the route and the endpoints of non-metallic pipelines. The shock-proof pig sondes can be combined with fiberglass or location cables and is suitable for use in calibration pigs. (see technical manual for details)
| MLS 55-1 | MLS 55-2 | MLS 55-3 | MLS 55-4 | MLS 100 | ||
| Frequencies | 9.82 kHz | 39.28 kHz | 33 kHz | 8.44 kHz | 9.82 kHz | |
| Diameter | 18.5 mm | 18.5 mm | 18.5 mm | 18.5 mm | 35 mm | |
| Locating depth | up to 5 m | up to 5 m | up to 5 m | up to 5 m | up to 5 m | |
| Power supply | 1 piece battery 6 V (Varta V 28 PX or Duracell PX 28 L) | |||||
| Operating time | approx. 12 hours | |||||
|
Frame antenna SS-2
Frame antenna for inductive coupling of metallic lines and cables for Ferrolux Generator FLG 10
- Frequency: 8440 Hz
- Power: max. 10 W
Separation Filter
Separation filter to couple audio frequency generators (and TDRs)
to energized low voltage cables
| Type | Frequencies | max. power | max. voltage | ||||||
| TF 2 | 8 … 10 kHz | 2 Watt | 450 V | ||||||
| TF 2050 | 8 … 10 kHz | 10 Watt | 250 V | ||||||
| AF Adapter | 10 … 39 kHz | 10 Watt | 250 V | ||||||
|
TF 2 TF 2050 AF Adapter
|
Separation transformer LTR 05
Separation transformer to feed in audio frequencies for the twisted field fault location on cables with voltaged neighbouring cables.
- Frequencies: 400 Hz … 10 kHz
- Power: 50 Watt
|
Cable reel HK 25
with 25 m of extention lead, e.g. to separate ground rod from target line to be located.
|
Ground rod EB 35
Length approx. 400 mm, with drill hole for banana plug and knurled nut for direct connection.
|
|
|
Fiberglass pig sonde feeder or location cables
Various lengths and diameters on a reel. GOK 30
| KEZ 50 | 50 m | for pinpointing pig sonde (not included) |
| GOK 30 | 30 m | with conductive wire (pig sonde not included) |
| GOK 60 | 60 m | with conductive wire (pig sonde not included) |
| GOK 100 | 100 m | with conductive wire (pig sonde not included) |
| GOK 60-K | 60 m | with passive sonde for pinpointing |
| GOK A-10 | 30 m | with acoustic sonde for locating with acoustic receiver |
GOK A-10