HPG 100 AC HV – Test Equipment 100kV AC / 130 kV DC
HPG 100 AC HV – Test Equipment 100kV AC / 130 kV DC
HPA 100 AC
HPA 130 DC (with optional rectifier HGL 130)
High Voltage Test System
Control instrument
The control instruments HSG 10 – 1 is used for controlling the high voltage transformers of the type HTR 100.
It consists of a variac, test meters for measuring the current and high voltage, operational components for the high voltage spark gap, a timer for the test duration and safety circuit.
Transformer
The low voltage winding can be supplied continuously from zero to the maximum value of the HSG 10-1 so that a certain output is available for a pre-determined period. The operating duration depends on the application ranging from a few minutes to continuous operation.
The test transformer is single pole insulated and is mounted in a insulated cylinder with top and bottom flanges. The insulation material is primarily oil impregnated paper.
Control Unit HSG 10 – 1
| Output | 5 kVA |
| Short term output (1h) | 10 kVA |
| Primary voltage | 220 V |
| Outgoing voltage | 0 … 250 V |
| kV-Measuring range (alternative) |
50 / 100 / 150 kV |
| Dimensions | 520 x 430 x 465 mm |
| Weight | 75 kg |
Transformer HTR 100
| Rated voltage | 100 kV AC 130 kV DC with opt. rectifier |
| Continuous output | 5 kVA |
| Rated current | 50 mA |
| Short circuit output | 10 kVA |
| Frequency | 50 Hz or 60 Hz |
| Short circuit voltage | approx. 5 % |
| PD at rated voltage | > 1 pC |
| Weight | approx. 225 kg |