ENPA | Kablo Test ve Arıza Bulma Cihazları
  • Enpa
  • Ürünler
  • İletişim
Home » Güç Kablosu/Test ve Teşhis » Dielektrik Teşhis ve Kısmi Boşalım Ölçümü » CDS – Integral Cable Diagnosis for PE / XLPE / Paper
  • Türkçe
  • English
  • İmajlar

CDS – Integral Cable Diagnosis for PE / XLPE / Paper

CDS – Integral Cable Diagnosis for PE / XLPE / Paper

The portable combined CDS is used as universal dielectric diagnostic system on PE / XLPE insulated cables as well as paper insulated cables worldwide. It combines the known methods of Isothermal Relaxation Current measurement (IRC-Analysis) and Voltage Return Method (RVM-Analysis) for aging and deterioration diagnostics. Due to the low charging voltage of the measurement the CDS works absolutely non destructive.

The diagnosis of PE / XLPE cables applies for evaluation of an IRC measurement a software-module with neuro-fuzzy-extension. The intelligent multi-stage evaluation software take into consideration the special construction criteria of the test object and categorises the condition of the test object, including an anticipated maximum residual voltage level.

The software includes a database with automatic research for calculation of voltage withstand prognosis values according to data material of the standard DIN VDE 0276 as well as the protocolling of the diagnostic results.

The RVM cable evaluation is done using proven standardised factors and threshold values.

The opening of the electric power markets and new forms of asset management lead to the need to increase life cycles of installed energy components and to be more economic regarding  existing underground installations. Using integral diagnostics, the cable operator has a valuable tool for non-destructive analysis of the cable network. This condition based maintenance makes planning easier whether to repair or replace an existing cable.

Features

  • Absolutely non-destructive condition evaluation of
    PE / XLPE / paper-oil insulated cable systems
  • Simple operation and automatic measurement procedures
  • Three-phase parallel measurement for current and voltage – duration of a complete measurement 1 hour
  • Extended dynamic range for IRC measurement
    for long cable segments
  • Measurement of charging current during formation
  • Improved filters
  • Extended capacity of internal rechargeable battery
    for serial measurements
  • Extended formation voltage up to 5 kV –
    suitable for diagnosis on HV cables
 

  • Güç Kablosu / Arıza Tespit
    • Kablo Test Arabaları ve Sistemleri
    • Portatif Sistemler
    • TDR Time Domain Reflektometre
    • Darbe Jeneratörleri
    • Noktasal Tespit
    • Yakma Tespit Cihazları
    • Kılıf Test ve Arıza Tespit Cihazları
    • Yeraltı Arıza Tespit
  • Güç Kablosu/Test ve Teşhis
    • VLF-Test Systems: Very Low Frequency 0.1 Hz Test
    • DC-Test Sistemleri
    • AC- Test Sistemleri
    • Dielektrik Teşhis ve Kısmi Boşalım Ölçümü
  • Power Cable and Cable Selection
    • Kablo Tanıma
    • Faz Tanıma
  • Telekomünikasyon Kablosu
    • TDR Time Domain Reflektometre
    • Köprü Test Cihazları
    • Fault Converter
    • Tetkik Ölçüm
    • Noktasal Tespit (Telekomünikasyon)
  • Boru Hatlarında Sızıntı Tespit
    • Sızıntı Tespit Arabası
    • Sızıntı izleme (Monitoring)
    • Akıntı Ölçümleri
    • Gaz ile Noktasal Tespit
    • Bağdaştırmalı Sızıntı Tespit
    • Akustik Nokta Tespit
    • Metal Olmayan Borularda Tespit
  • Kablo ve Boru Hatlarında Tespit
    • Kablo ve Boru Hattı Tespit
    • Aksesuarlar
    • İşaretleyici
  • CCTV Tespit
    • Kamera
Copyright © 2011 www.enpa.com.tr Tüm hakları saklıdır.