ENPA | Kablo Test ve Arıza Bulma Cihazları
  • Enpa
  • Ürünler
  • İletişim
Home » Güç Kablosu/Test ve Teşhis » Dielektrik Teşhis ve Kısmi Boşalım Ölçümü » TE PDS
  • Türkçe
  • English
  • İmajlar

TE PDS

TE PDS

The TE PDS provides an inductive and a capacitive sensor for quality assessment on various electrical installations. The most common application for this instrument is to check the quality in terms of PD of joints and terminations immediately after installation. The TE PDS is used exclusively on insulated HV installations.

Detecting possible weakspots is done with the capacitive sensor, which picks up electric field changes due to PD. The intensity of the signal in pico coulomb decreases with increasing distance to the PD source and is immediately transformed into a dB-value and displayed. This change of signal level leads to the exact location of the PD.

The TE PDS is also applicable on shielded joints if the shield is grounded on both sides of the joint. This measurement uses the built-in inductive sensor. The course of the signal level along the joint indicates the exact location where highest level is indicated closest to the PD fault location.

PD pulses at the respective faults are reliabley detected and evaluated by the integrated VHF senors in the frequency range of 100 MHz. A high indication will provide higher reliability and quantification of the weakspot. The signal levels are indicated visually and acoustically.

Features

  • dual sensor system for capacitive and inductive PD detection
  • rugged and weatherproof plastic housing with LED PD level indication
  • insulated extension rod for different application situations
  • acoustic indication with frequency modulation
  • visual battery status indication
  • VHF frequency range
  • long operating time and automatic switch-off
  • simple operation and handling

Scope of Delivery

  • TE PDS instrument
  • Insulated extention handle
  • Set of batteries
 

  • Güç Kablosu / Arıza Tespit
    • Kablo Test Arabaları ve Sistemleri
    • Portatif Sistemler
    • TDR Time Domain Reflektometre
    • Darbe Jeneratörleri
    • Noktasal Tespit
    • Yakma Tespit Cihazları
    • Kılıf Test ve Arıza Tespit Cihazları
    • Yeraltı Arıza Tespit
  • Güç Kablosu/Test ve Teşhis
    • VLF-Test Systems: Very Low Frequency 0.1 Hz Test
    • DC-Test Sistemleri
    • AC- Test Sistemleri
    • Dielektrik Teşhis ve Kısmi Boşalım Ölçümü
  • Power Cable and Cable Selection
    • Kablo Tanıma
    • Faz Tanıma
  • Telekomünikasyon Kablosu
    • TDR Time Domain Reflektometre
    • Köprü Test Cihazları
    • Fault Converter
    • Tetkik Ölçüm
    • Noktasal Tespit (Telekomünikasyon)
  • Boru Hatlarında Sızıntı Tespit
    • Sızıntı Tespit Arabası
    • Sızıntı izleme (Monitoring)
    • Akıntı Ölçümleri
    • Gaz ile Noktasal Tespit
    • Bağdaştırmalı Sızıntı Tespit
    • Akustik Nokta Tespit
    • Metal Olmayan Borularda Tespit
  • Kablo ve Boru Hatlarında Tespit
    • Kablo ve Boru Hattı Tespit
    • Aksesuarlar
    • İşaretleyici
  • CCTV Tespit
    • Kamera
Copyright © 2011 www.enpa.com.tr Tüm hakları saklıdır.