VLF CR 40 kV
VLF CR 40 kV
SebaKMT´s portable VLF 60 is designed for HV-tests on cables with a rated voltage of 35 kV or the VLF 40 for cables up to 22kV.
Using the patented SebaKMT Cosine-Square Wave shaped voltage form, with energy regeneration, weak spots in PE/XLPE and paper insulated lead cables can be brought to a breakdown quickly, without unnecessary strain on the cable insulation.
High quality voltage sources and the use of a semi-conductor switch, free of wear for the generation of a regular polarity reversal, guarantee a long life-span. A polarity transition corresponding to the 50 Hz mains voltage is a salient feature.
The optional leakage current measurement permits a direct quality assessment during the test procedure.
Technical Features:
![]() |
Powerful, portable and universal cable test system.
|
![]() |
Modular design (power module and control module) with an individual weight of approx. 50 kg
|
![]() |
Optional module “leakage current measurement” and “output doubling” to individually suit the system to specific test requirements.
|
![]() |
Optional Module “data recording” for comfortable und easy on the spot recording of the test results, the central administration of the test parameters and for reproduceable test procedures.
|
![]() |
Automatic breakdown recognition
|
![]() |
Fast, on the spot installation without complicated setup, with shockproof sockets and integrated discharge devices to comply with the highest safety standards.
|
![]() |
With the patented technique of energy storage during the polarity reversal of the VLF voltage, it is possible to achieve a very low power consumption while simultaneously achieving a high testing capacitance.
|
![]() |
VLF 0.1 Hz testing is recommended, allowing high cable capacitance, and is the most effective method for testing PE and XLPE cables.
|
Scope of Delivery:
![]() |
Basic instrument
|
![]() |
HV-connection cable 5 m
|
![]() |
Connection cable
|
![]() |
Accessory bag
|
![]() |
Earth line 5 m
|
![]() |
Operating manual
|
Order Description:
![]() |
VLF 40 Basis Article No.: 900 4500
|
![]() |
VLF 40 Plus Article No.: 900 4501
|
![]() |
VLF 60 Basis Article No.: 900 4502
|
![]() |
VLF 60 Plus Article No.: 900 4503
|
Options:
![]() |
Hard copy print-out Article No.: 900 4505
|
![]() |
Protocol Article No.: 900 4504
|
![]() |
Breakdown recognition Article No.: 900 4821
|
![]() |
Leakage current measurement Article No.: 900 4822
|
NEW
![]() |
portable, 0.1 Hz VLF Test System up to 60 kV
|
![]() |
automatic parameter adjustment by means of a chip-card
|
![]() |
integrated leakage current measurement
|
![]() |
integrated protocol option
|
![]() |
integrated breakdown recognition
|